Telnet Commands
Port: support 3 ports of 23/1023/2023•
Multi-connections: Projector could receive commands from •
different ports at the same time
Command Format: Follow RS232 command format (sup-•
port both of ASCII and HEX)
Command Response: Follow RS232 return message.•
Lead Code Projector ID Command ID space variable carriage
return
~ X X X X X n CR
Fix code One
Digit~
00 Dened by Optoma 2 or
3 Digit. See the Follow
content
One Digit Per item
Denition
Fix code One
Digit
AMX Device Discovery commands
UDP : 239.255.250.250•
Port No. : 9131•
Each UDP broadcast information as below are updated •
around 40 seconds
When the data length is greater or shorter than indicated by the data length
code, the projector returns the error code to computer.
Command Description Remark (Parameter)
Device-UUID MAC address (Hex value without’ ‘:’ separa-
tor)
12 digits
Device-SKD-
Class
The Duet DeviceSdk class name VideoProjector
Device-Make Maker name MakerPXLW
Device-Model Model name Projector
Cong-URL Device’s IP address
LAN IP address is shown up if LAN IP ad-
dress is valid.
Wireless LAN IP address is shown up if
Wireless LAN IP address is valid.
http://xxx.xxx.xxx.xxx/index.html
Revision The revision must follow a major.minor.micro
scheme. The revision is only increased if the
command protocol is modied.
1.0.0
Comments to this Manuals